Temperature sensors position in chemical reactors: The use of CFD

Valentina Busini, Matteo Rizzotto

and

Renato Rota

Politecnico di Milano, Italy

S

tatement of the Problem: Runaway reactions have always been a serious issue for the chemical industry. Failures that may

lead to this type of accident may be different: block of the impeller, loss of the reactor temperature control, error in the

loading of reagents. The rapid detection of this phenomena is crucial. One of the most widely used preventive systems is the

so-called early warning system, which allows to give an early warning at the beginning of the fugitive reaction. Due to non-

homogeneity of the temperature inside the reactor, the positioning of the sensors is of crucial importance. In fact, an incorrect

localization of the temperature probe could lead to a false alarm, which would undermine the early warning system. The

objective of this work is the computational fluid dynamic (CFD) simulation of different failure scenarios, in order to determine

the best location of the temperature sensors. Methodology & Theoretical Orientation: For this work a semi-batch reactor was

used to simulate an accident in a pilot scale reactor. An impeller fault and a reagent loading error has been investigated in CFD

using a new kinetic model for liquid reactions, implemented in ANSYS Fluent. Findings: Differently fromwhat is present in the

literature, CFD results show that depending on the incident considered, the best position for the thermocouple varies within

the reactor. For the impeller fault the best position is in the upper region of the reactor, while for the loading error accident the

best position is always in the proximity of the reagent mass. Conclusion & Significance: The simulations performed show the

usefulness of CFD in analyzing these kind of problems and that there is no unique positioning of thermocouples which would

be optimal to early-detect every runaway scenario. Here rises the importance of redundant measurements in a reactor.

Biography

Valentina Busini has her expertise in safety engineering and bioengineering. In particular, with regard to industrial safety, she usually works on the analysis of

the consequences of industrial events related to emerging risks, such as the CFD modeling of heavy gas dispersion in complex environments, and the definition

of methodologies for the evaluation of industrial accidents triggered by natural events (the so-called NaTech events). As far as bioengineering is concerned, she

has focused on the interactions between materials and biomolecules, both for biocompatibility studies and for the development of protein separation processes.

valentina.busini@polimi.it

Valentina Busini et al., J Adv Chem Eng 2017, 7:2(Suppl)

DOI: 10.4172/2090-4568-C1-002