International Conference on

ATP as a useful method in controlling cleanliness of flexible endoscopes

Paul J Caesar

University Medical Center Groningen, Netherlands

A

lthough quality of reprocessing FES has improved over the past decades and permanent controls of process parameters in

the automated endoscope washers (AEW) are continuously performed, improper or ineffective cleaning, disinfection, drying

and storage (reprocessing) of reusable flexible endoscopes (FES) can pose a serious infection risk to patients. Despite of all quality

improvements and a strong believe in validated process parameters of the AEW, in the UMCG FES with channels are still frequently

and routinely microbiological (bacterial) sampled by retrograde flushing of all channels. For example, based on historical outcomes,

each duodenoscope is sampled every week. Although FES safely passed the process in the AEW, a part of reprocessed FES showed

to be positive in microbiological cultures, even with resistant bacteria. This additional screening of microbial quality of reprocessed

FES could be regarded as an essential method to detect pitfalls in reprocessing or the state of art quality of FES especially in FES with

channels. However, microbial screening is labor-intensive (and thus cost-expensive), takes a long time and only microbial (bacterial)

contamination is verifiable. Based on literature and two short surveys in which we studied the use of ATP (adenosine triphosphate)

bioluminescence as an alternative in checking the cleanliness of reprocessed ENT-endoscopes and duodenoscopes, we conclude

that ATP is a quick, easy and reliable method for regularly monitoring the cleanliness of reprocessed FES. Because it’s broader

spectrum including all possible organic contamination (e.g., tissue), it has a positive effect on the whole quality and safety process

on reprocessing FES and a safe release and use for following patients. ATP can replace high frequent routine microbiological testing,

which should only be indicated on clinical problems possible related with the use of FES or when outcomes on ATP indicates the need

of further and more in-depth research.

Biography

Paul J Caesar has 25 years of experience in hygiene and infection control. He is presently working as an Expert in Medical Devices and Reprocessing Flexible Endoscopes

in the Department of Medical Affairs, Quality and Safety of one of the largest university hospitals in the Netherlands. He has published papers on endoscope reprocessing,

hand hygiene and other items on infection control. He has also developed teaching programs on reprocessing flexible endoscopes and cleaning, disinfection and sterilization

of medical devices and a nationwide education program on hygiene and infection control for infection control practitioners in hospitals and public health. He is a chair of a

Dutch Expert Group for reprocessing flexible endoscopes.

p.caesar@umcg.nl

Paul J Caesar, J Infect Dis Ther 2016, 4:4(Suppl)

http://dx.doi.org/10.4172/2332-0877.C1.008