Previous Page  17 / 19 Next Page
Information
Show Menu
Previous Page 17 / 19 Next Page
Page Background

Page 31

Notes:

conferenceseries

.com

Volume 7

Journal of Infectious Diseases & Therapy

Infectious Diseases & Endocrinology 2019

February 27-28, 2019

February 27-28, 2019 Tokyo, Japan

Infectious Diseases, Diabetes and Endocrinology

Global Experts Meeting on

Maham S et al., J Infect Dis Ther 2019, Volume 7

DOI: 10.4172/2332-0877-C2-062

BACTEC and conventional culture systems comparison to isolate of microorganisms from blood

and other sterile body fluids

Maham S

1

, Shirvani F

1

, Hadipour Jahromi M

1

, Fallah F

1

, Razavi S S

1

, Nikfarjam A

2

and Rahbar M

2

1

Shahid Beheshti University of Medical Sciences, Iran

2

Ministry of Health and Medical Education, Iran

B

lood stream infectious diseases are prevalent in children and adults. Rapid and accurate diagnosis of bloodstream infections

are primarily based on conventional culture results, which saves time and prevents empiric treatment. This study aims to

BACTEC and conventional culture systems comparison to isolate of microorganisms from blood and other sterile body fluids,

on blood specimens collected from three training hospitals in Tehran, Iran. BACTEC 9120 and conventional methods were

used for isolation of microorganism from specimens including blood and other body fluid samples collected from patients

hospitalized in the selected hospitals during the study period, from April to June 2009. Time for positive and negative results

and hospital charge were estimated for the two culture methods. In total 747 specimens were possessed by BACTEC 9120

systems and 787 by conventional method. Patients aged between 3 days and 8 years old, (mean 11.4±21.9 years); 52% of patients

were male and 48% female; Out of 747 specimens were possessed by BACTEC 9120 system, 26% (196/747) and from 787

specimens cultured by conventional method 5% (49/787) were positive (p<0.05). Hospital stay was 13.8±12.9 days in BACTEC

9120 and 17.9±14.9 days in Conventional method (p<0.05), respectively. Time for positivity by BACTEC system was 3.8±1.1

days and 5.9±2.5 days in conventional method (p<0.05), treatment response showed 1.8 day earlier result in patients that their

specimens were processed by BACTEC 9120 system. Death rate in BACTEC 9120 method was 6% and 11% in conventional

method (p>0.05). In conclusion implementation of BACTEC system for microbiologic detection of pathogens decreases the

admission time and early diagnosis and treatment results are cost effective for patient management and prevention of antibiotic

resistance.

Biography

Maham S is working as the Manager of Pediatric Infections Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran. His research interest

is in medical and diagnostic methods.

fafallah@sbmu.ac.ir