Dersleri yüzünden oldukça stresli bir ruh haline sikiş hikayeleri bürünüp özel matematik dersinden önce rahatlayabilmek için amatör pornolar kendisini yatak odasına kapatan genç adam telefonundan porno resimleri açtığı porno filmini keyifle seyir ederek yatağını mobil porno okşar ruh dinlendirici olduğunu iddia ettikleri özel sex resim bir masaj salonunda çalışan genç masör hem sağlık hem de huzur sikiş için gelip masaj yaptıracak olan kadını gördüğünde porn nutku tutulur tüm gün boyu seksi lezbiyenleri sikiş dikizleyerek onları en savunmasız anlarında fotoğraflayan azılı erkek lavaboya geçerek fotoğraflara bakıp koca yarağını keyifle okşamaya başlar

GET THE APP

Validation Of ICP-OES And AAS Method For The Determination Of Magnesium In Infant And Followon Formula | 52857
ISSN: 2155-9872

Journal of Analytical & Bioanalytical Techniques
Open Access

Our Group organises 3000+ Global Conferenceseries Events every year across USA, Europe & Asia with support from 1000 more scientific Societies and Publishes 700+ Open Access Journals which contains over 50000 eminent personalities, reputed scientists as editorial board members.

Open Access Journals gaining more Readers and Citations
700 Journals and 15,000,000 Readers Each Journal is getting 25,000+ Readers

This Readership is 10 times more when compared to other Subscription Journals (Source: Google Analytics)

Validation of ICP-OES and AAS method for the determination of magnesium in infant and followon formula

7th International Conference and Exhibition on Analytical & Bioanalytical Techniques

Kyung Mi Hwang, Hyeon Suk Ham, Doo Jin Lee, Hwa Jung Lee, Soo Jung Hu, Yoon Jung Kang, Yong Woon Shin, Myung Hee Moon, Jin Hwan Hong and Hae Seong Yoon

National Institute of Food and Drug Safety Evaluation, Korea

Posters & Accepted Abstracts: J Anal Bioanal Tech

DOI: 10.4172/2155-9872.C1.025

Abstract
This study was conducted to establish the standard method for the contents of magnesium in infant and follow-on formula. Magnesium was extracted from 0.2 g certified reference material (NIST SRM 1849a) with 70% HNO3 and 7 ml by the MARS5 microwave lab station. Digests were then analyzed with Perkin-Elmer Optima 8300 inductively coupled plasma-optical emission spectrometer (ICP-OES) and Perkin-Elmer Analyst 700 atomic absorption spectrophotometer (AAS). Performance parameters were estimated for linearity, limits of detection (LOD) and limits of quantification (LOQ), accuracy and precision. The linearity of standard solution with correlation coefficient was higher than 0.999 in range of 0.05-1.5 mg/L. LOD were 0.01 mg/L and limits of quantification were 0.03 mg/L. Recovery of CRM were determined as approximately 100%. Currently, optimized method showed high accuracy (>90%) and precision was 0.2% relative standard deviation (RSD). The method was found to be suitable for routine quality control monitoring of infant and follow-on formulas.
Biography

Kyung Mi Hwang has completed her PhD from Pusan National University in Korea and Post-doctoral studies from Konkuk University, School of Bioinformatics. She is a Scientific Officer of Nutrition and Functional Food Research Team, National Institute of Food and Drug Safety Evaluation. She has published more than 10 papers in reputed journals.

Email: sprite11@korea.kr

Top