Our Group organises 3000+ Global Conferenceseries Events every year across USA, Europe & Asia with support from 1000 more scientific Societies and Publishes 700+ Open Access Journals which contains over 50000 eminent personalities, reputed scientists as editorial board members.
Brominated flame retardants (BFRs) are industrial chemicals widely used in consumer products to enhance their ignition
resistance. Since in most applications these chemicals are used additively, they can transfer from such products into the
environment. The toxicity of some BFRs has led to concern about human exposure. Ingestion of indoor settled dust appears
to represent a major pathway of exposure to BFRs. However, assessment of human exposure is rendered uncertain because of
a lack of knowledge about spatial and temporal variation, dust particle size and sampling collection method. Thus, the study
aims to investigate the most important factors influencing human exposure assessments of BFRs via indoor dust ingestion.
Concentrations of polybrominated diphenyl ethers (PBDEs) and selected novel brominated flame retardants (NBFRs) were
measured in 305 indoor dust samples from different homes in Birmingham, UK. Our results revealed that substantial withinroom
and within-home spatial variability in BFR concentrations was apparent between two floor areas and between elevated
surface and floor dust, due to the varying distances of sampled surfaces from potential BFR sources. BFR concentrations in
elevated surface dust exceeded significantly those in floor dust from the same rooms. Considerable within-room and withinhome
temporal variability in BFR concentrations was apparent over a nine month sampling period, that is likely attributable
to changes in room contents. Exposure estimates based on analysis of a dust sample taken from one specific floor area at one
specific point in time may not be entirely representative of human exposure in that room. While concentrations of higher
brominated compounds did not differ significantly between different dust particle size fractions, those of lower brominated
compounds were significantly higher in the finest particle size, underlining the importance of selecting the most appropriate
dust particle size for the purpose of exposure assessment. BFR concentrations in researcher-collected dust were higher than
those in household vacuum dust.
Recent Publications
1. Björklund, J A, U Sellstrom, C A de Wit, M Aune, S Lignell and P O Darnerud (2012) Comparisons of polybrominated
diphenyl ether and hexabromocyclododecane concentrations in dust collected with two sampling methods and matched
breast milk samples. Indoor Air 22(4):279-288.
2. Cao Z G, G Yu, Y S Chen, Q M Cao, H Fiedler, S B Deng, J Huang and B Wang (2012) Particle size: a missing factor in risk
assessment of human exposure to toxic chemicals in settled indoor dust. Environment International 49:24-30.
3. Fang M and H M Stapleton (2014) Evaluating the bioaccessibility of flame retardants in house dust using an in vitro tenax
bead-assisted sorptive physiologically based method. Environmental Science & Technology 48(22):13323-13330.
4. Mercier F, P Glorennec, O Thomas and B Le Bot (2011) Organic contamination of settled house dust, a review for exposure
assessment purposes. Environmental Science & Technology 45(16):6716-6727.
5. Muenhor D and S Harrad (2012) Within-room and within-building temporal and spatial variations in concentrations of
polybrominated diphenyl ethers (PBDEs) in indoor dust. Environment International 47:23-27.
Biography
Layla Salih Al-Omran is interested in analysis of organic and inorganic pollutants in both biotic and abiotic samples. She has an extensive experience in human exposure assessments of persistent organic pollutants (POPs) in indoor dust. She has built this experience during her PhD study at University of Birmingham, UK. The study involves investigating of the most important factors that affects human exposure assessments of legacy and novel brominated flame retardants via indoor dust ingestion, such as spatial and temporal variations, dust particle size, sampling methods, dust loading and organic carbon content. It has been suggested that without taking into account all of these factors, the exposure assessment will not be an entirely representative metric of exposure. This work is a part of her PhD thesis at University of Birmingham UK during 2012-2016. She has published four research papers regarding to these factors.