ISSN: 2155-9872

Journal of Analytical & Bioanalytical Techniques
Open Access

Our Group organises 3000+ Global Conferenceseries Events every year across USA, Europe & Asia with support from 1000 more scientific Societies and Publishes 700+ Open Access Journals which contains over 50000 eminent personalities, reputed scientists as editorial board members.

Open Access Journals gaining more Readers and Citations
700 Journals and 15,000,000 Readers Each Journal is getting 25,000+ Readers

This Readership is 10 times more when compared to other Subscription Journals (Source: Google Analytics)

Development and validation of bioanalytical method for the quantitative estimation of duloxetine in human plasma using lcms/ ms

2nd International Conference on Analytical & Bioanalytical Techniques

S. P. Pattanayak

ScientificTracks Abstracts: J Anal Bioanal Techniques

DOI: 10.4172/2155-9872.S1.02

Abstract
A simple, sensitive and accurate liquid chromatography positive ion atmospheric pressure ionization tandem mass spectrometry method was developed and validated for the quantifi cation of duloxetine in human plasma. Following liquid�liquid extraction, the analyte was separated using an isocratic mobile phase on a reverse phase column (Xterra MS C18 (5�¼m,100�3.0mm)) at a column oven temperature of 30�C and analysed by MS/MS (Sciex API 3000) in the multiple reaction monitoring mode using the respective [M+H] + ions , m/z 298.2 to154.10 and 298.2 to 44.0 for duloxetine and m/z 310.0 to 44.0 for fl uoxetine (internal standard). Th e isocratic mobile phase composition was a mixture of acetonitrile:0.1% formic acid (50:50 v/v), which was pumped at a fl ow rate of 1.0mL/min with split ration of 60:40(v/v). Th e assay exhibited a linear dynamic range of 0.345 to 185.463ng/ml for duloxetine in human plasma. Th e lower limit of quantifi cation was 0.345 ng/ml with the relative standard deviation of less than 2.41% (n=4). Acceptable precision and accuracy were obtained for concentrations over the standard curve range. No signifi cant degradation was observed for duloxetine in human plasma when stored at room temperature (4h), when subjected to freeze and thaw cycles (3 cycles). Th e overall absolute recovery is 76.92 % to 85.89%. No matrix suppression was found in the method (94.64%to 100.33%). Because of short run time of 2.0 minutes per sample, the maximum throughput of approximately 500 human plasma samples can be analysed per day in compliance with the current regulatory requirements, which makes it more economical and rapid method of analysis.
Biography

S. P. Pattanayak is working as an Assistant Professor in the University, Birla Institute of Technology (BIT), Mesra, a technical university under UGC, India established in 1955 and has done his master?s and doctoral research on preclinical breast cancer research. He has published more than 24 research papers and 25 conference proceedings and serving as an editorial board member and reviewer of repute in some National (including India Government of fi cial publications) and International journals. He has hands on experience in clinical research. He also works as a visiting professor and external examiner in some reputed organizations of India.

Top