ISSN: 2155-9872

Journal of Analytical & Bioanalytical Techniques
Open Access

Our Group organises 3000+ Global Conferenceseries Events every year across USA, Europe & Asia with support from 1000 more scientific Societies and Publishes 700+ Open Access Journals which contains over 50000 eminent personalities, reputed scientists as editorial board members.

Open Access Journals gaining more Readers and Citations
700 Journals and 15,000,000 Readers Each Journal is getting 25,000+ Readers

This Readership is 10 times more when compared to other Subscription Journals (Source: Google Analytics)

Determination of amlodipine in human plasma by liquid chromatography�tandem mass spectrometry and its application to pharmacokinetic & bioequivalence studies

6th International Conference and Exhibition on Analytical & Bioanalytical Techniques

Syed N Alvi, Rajaa F Hussein, Reem Al Swayeh, Saleh Al Dgither and Muhammad M Hammami

King Faisal Specialist Hospital & Research Center, Saudi Arabia

ScientificTracks Abstracts-Workshop: J Anal Bioanal Tech

DOI: 10.4172/2155-9872.S1.021

Abstract
A rapid Liquid Chromatographic-Tandem Mass Spectrometric (LC-MS/MS) assay for the measurement of amlodipine level in human plasma was developed and validated. Amlodipine and tizanidine (IS) were extracted from plasma using mixture of dichloromethane and tertiary butyl methyl ether (1:3, v:v) and reconstituted with 100 �¼l mixture of methanol and water (1:1, v:v). The mobile phase consisted of acetonitrile and 0.1% formic acid (80:20, v:v). Analysis was performed at room temperature using a reversed phase Atlantis dC18 (2.1x100 mm, 3 �¼m) column. The components of interest were detected in the positive ion mode of electrospray ionization using transition 409.8 â�� 238.4 and 254.3 â�� 43.9 for amlodipine and the IS, respectively. The relationship between amlodipine concentration in plasma and peak height ratio of amlodipine to IS was linear â�¥0.9868 in the range of 0.2â��20 ng/ ml; intra and inter-day accuracy between 101-114%, and coefficient of variations were â�¤14.4%. The quantification limit of amlodipine in 0.5 ml plasma was 0.2 ng/ml and the detection limit was 0.1 ng/ml. The method was successfully validated and applied in a bioequivalence study of four tablet formulations of amlodipine.
Biography

Syed N Alvi obtained his PhD in Chemistry from Osmania University, Hyderabad, India in 2001. He is currently Scientist at King Faisal Specialist Hospital & Research Centre, Riyadh, Saudi Arabia. He his research interest includes method development and validation and application for pharmacokinetic and bioequivalence studies.

Email: salvi@kfshrc.edu.sa

Top