Dersleri yüzünden oldukça stresli bir ruh haline sikiş hikayeleri bürünüp özel matematik dersinden önce rahatlayabilmek için amatör pornolar kendisini yatak odasına kapatan genç adam telefonundan porno resimleri açtığı porno filmini keyifle seyir ederek yatağını mobil porno okşar ruh dinlendirici olduğunu iddia ettikleri özel sex resim bir masaj salonunda çalışan genç masör hem sağlık hem de huzur sikiş için gelip masaj yaptıracak olan kadını gördüğünde porn nutku tutulur tüm gün boyu seksi lezbiyenleri sikiş dikizleyerek onları en savunmasız anlarında fotoğraflayan azılı erkek lavaboya geçerek fotoğraflara bakıp koca yarağını keyifle okşamaya başlar

GET THE APP

Can We Improve Shear Stability Of Intramedullary Nail For The Fixation Of Distal Tibial Fractures | 29765
ISSN: 1662-100X

Journal of Biomimetics Biomaterials and Tissue Engineering
Open Access

Our Group organises 3000+ Global Conferenceseries Events every year across USA, Europe & Asia with support from 1000 more scientific Societies and Publishes 700+ Open Access Journals which contains over 50000 eminent personalities, reputed scientists as editorial board members.

Open Access Journals gaining more Readers and Citations
700 Journals and 15,000,000 Readers Each Journal is getting 25,000+ Readers

This Readership is 10 times more when compared to other Subscription Journals (Source: Google Analytics)

Can we improve shear stability of intramedullary nail for the fixation of distal tibial fractures


Jalil Nourisa1, Ghadir Shaygan2, Gholamreza Rouhi1

: Biomim Biomater Tissue Eng

Abstract
Potential for malalignment is the main disadvantage of IM nailing, which can occur mainly as a result of reduced bone-implant contact at the distal quarter and high shear interfragmentary movements (IFM). The goal of this study was to evaluate the performance of a new designed IM nailing system in which an extra screw could be inserted right above the fracture gap. For this purpose, a three-dimensional finite element model of tibia-nail system was constructed by considering a 3mm transverse gap at the distal quarter. Physiological boundary conditions were applied, and three different materials, i.e. stainless steel, titanium, and carbon/ epoxy, were assumed for the IM nail. The von Mises stress, interfragmentary movements, and the specific production of different tissue phenotypes were obtained to make a comparison among different bone-nail constructs. Results of this study showed that inserting an extra screw above the fracture gap can cause a dramatic reduction in the shear IFM. However, since axial IFM mainly occurred as a result of bony fragments��? tilting, insertion of extra screw also restricted axial movements. Thus, in order to preserve stimulatory axial micromotion, the proposed design is recommended when an IM nail with a low young modulus, such carbon/ epoxy, is used. The finite element model was validated with the results of in vitro tests on cadaver.
Biography

Gholamreza Rouhi received his BSc and MSc degrees from Sharif University of Technology, and his PhD from the University of Calgary for his investigations on bone remodelling and resorption theories. After earning his PhD degree, he joined University of Ottawa, Canada, as Assistant Professor. He then moved back to Iran and was recruited by Amirkabir University of Technology (AUT). He is involved in various projects including: Bone fracture healing; bone remodelling theories; bone-implants interaction; orthopaedic implants and prostheses; and biomechanics of articularcartilage. He is now the Director and Principal Investigator of Orthopaedic & Dental Biomechanics Lab at AUT.

Relevant Topics
Top