New smartphone app for strabismus screening

Jorge Antonio Meireles-Teixeira

Federal University of Maranhão, Brazil

A

mblyopia is the major cause of unilateral low visual acuity among children and the most important cause of it is strabismus.

There are only few strabologists in any country, generating difficulties to early diagnosis of strabismus. That is the reason

we decided to work on a smartphone software able to perform strabismus screening and easy to be operated by non-medical

professionals. The software localizes the eyes of the subject and based on an algorithm similar to Krimsky method it can

disclose the strabismus of the patient (Fig. 1). We first check it with 224 subjects (Fig. 2) among strabismus patients (24) and

children and teenagers of public school (200) and it seemed to be reliable to detect the absence of strabismus (only two false

negative results compared with strabologists exam), even if it had a greater false positive diagnosis (31). But these false positive

results are not really important when talking about screening, once those patients will be referred to a specialist for a detailed

examination.

Recent Publications

1. Almeida J D S (2012) Computational methodology for automatic detection of strabismus in digital images through

Hirschberg test. Computers in Biology and Medicine 42: 135–146.

2. Carlton J, Kaltenthaler E (2011) Amblyopia and quality of life: a systematic review. Eye, London England. 25(4):

403–413.

3. Sousa De Almeida, João Dallyson, Silva Aristófanes Corrêa, Teixeira Jorge Antonio Meireles, Paiva Anselmo Cardoso,

Gattass Marcelo (2015) Computer-aidedmethodology for syndromic strabismus diagnosis. Journal of Digital Imaging.

27: 1-1.

4. Valente Thales Levi Azevedo, De Almeida João Dallyson Sousa, Silva Aristófanes Corrêa, Teixeira Jorge Antonio

Meireles, Gattass Marcelo (2017) Automatic Diagnosis of Strabismus in Digital Videos through Cover Test. Computer

Methods and Programs in Biomedicine 140: 295-305.

5. Weber K P et al. (2017) Strabismus Measurements with Novel Video Goggles. Ophthalmology 124(12):1849-1856.

Biography

Teacher at UFMA - Federal University of Maranhão [Official] Studied at the Federal University of São Paulo (UNIFESP) Studied Ophthalmology Residency at

Jundiaí Medical School Studied Medicine at UFMA - Federal University of Maranhão [Official] Studied at UFMA Went to Colégio Santa Tereza Lives in Sao Luis,

Brazil From São Luís, Brazil

jorgemeireles1@gmail.com

Jorge Antonio Meireles-Teixeira, J Clin Exp Ophthalmol 2018, Volume 9

DOI: 10.4172/2155-9570-C1-078