ISSN: 2155-9872

Journal of Analytical & Bioanalytical Techniques
Open Access

Our Group organises 3000+ Global Conferenceseries Events every year across USA, Europe & Asia with support from 1000 more scientific Societies and Publishes 700+ Open Access Journals which contains over 50000 eminent personalities, reputed scientists as editorial board members.

Open Access Journals gaining more Readers and Citations
700 Journals and 15,000,000 Readers Each Journal is getting 25,000+ Readers

This Readership is 10 times more when compared to other Subscription Journals (Source: Google Analytics)
  • Research Article   
  • J Anal Bioanal Tech 2022, Vol 13(7): 469
  • DOI: 10.4172/2155-9872.1000469

Development and Validation of RP-UHPLC Method for Determination of Sertraline in Bulk Drug and Dosage Form

V. Chaudhari*, S. Patil and S. P. Pawar
Poojya Sane Guruji Vidya Prasarak Mandals, College of Pharmacy, Shahada-425409 Dis-Nandurbar, Maharashtra, India
*Corresponding Author : V. Chaudhari, Poojya Sane Guruji Vidya Prasarak Mandals, College of Pharmacy, Shahada-425409 Dis-Nandurbar, Maharashtra, India, Email: vaishnavi4542@gmail.com

Received Date: Jun 27, 2022 / Published Date: Jul 24, 2022

Abstract

Objective: The new, rapid, sensitive, simple, precise and accurate Reversed- Phase Ultra High Performance Liquid Chromatography (RP-UHPLC) method was developed and validated for determination of Sertraline in bulk drug and Pharmaceutical dosage form.

Methods: The UV Spectrum of Sertraline in diluent showed maximum wavelength at 273nm. In RP-UHPLC method separation achieved by Agilent C18 (75mm×3.9mm, 2μm particle size) column using Acetonitrile :( 0.1%OPA) Water (80:20v/v) as mobile phase at flow rate 0.7ml/min. Injection volume is 20μl. RP-UHPLC detection carried out at 273nm.

Results: In RP-UHPLC method retention time was found to be 3.75min. The Calibration curve was found to be linear (r2=0.999) with concentration range of 10-50μg/ml. The Accuracy (% recovery) for Sertraline was found to be 99-100%. The % RSD (intra-day and inter precision) values are not more than 2% hence the developed methods are accurate and precise. The LOD and LOQ were found to be 0.2085μg/ml and 0.6321μg/ml respectively.

Conclusion: The developed method was validated with respect to linearity, accuracy, precision, robustness, ruggedness, LOD and LOQ as per ICH guidelines. The proposed method was used for routine analysis of Sertraline in Bulk drug and Solid dosage Form.

Citation: Chaudhari V, Patil S, Pawar SP (2022) Development and Validation of RP-UHPLC Method for Determination of Sertraline in Bulk Drug and Dosage Form. J Anal Bioanal Tech 10: 469. Doi: 10.4172/2155-9872.1000469