ISSN: 2155-9872

Journal of Analytical & Bioanalytical Techniques
Open Access

Our Group organises 3000+ Global Conferenceseries Events every year across USA, Europe & Asia with support from 1000 more scientific Societies and Publishes 700+ Open Access Journals which contains over 50000 eminent personalities, reputed scientists as editorial board members.

Open Access Journals gaining more Readers and Citations
700 Journals and 15,000,000 Readers Each Journal is getting 25,000+ Readers

This Readership is 10 times more when compared to other Subscription Journals (Source: Google Analytics)
  • Research Article   
  • J Anal Bioanal Tech 2018, Vol 9(2): 403
  • DOI: 10.4172/2155-9872.1000403

Validation of Miniaturized Particulate-Matter Real-Time Samplers for Characterizing Personal Polycyclic Aromatic Hydrocarbon Exposure

Beizhan Yan1*, Masha Pitiranggon1, James Ross1, Thomas Arthen-Engeland2, Andreas Stelter2 and Steven Chillrud N1
1Lamont-Doherty Earth Observatory of Columbia University, , Palisades, NY, USA
2, Bruker Daltonik GmbH, Bremen, Germany
*Corresponding Author : Beizhan Yan, Lamont-Doherty Earth Observatory of Columbia University, 61 Route 9W, Palisades, NY 10964, USA, Tel: 8453658448 Exn. 8453658155, Email: yanbz@ldeo.columbia.edu

Received Date: Mar 29, 2018 / Accepted Date: Apr 06, 2018 / Published Date: Apr 11, 2018

Abstract

This study validates the analysis of polycyclic aromatic hydrocarbons (PAHs) in microgram levels of particulate matter (PM) collected on filters by two low-flow rate, real-time monitors, microPEM™ and microAeth®. Particleassociated PAHs were analyzed by a coupling of a gas chromatograph to a sensitive, atmospheric-pressure laser ionization-mass spectrometer. Air particulate samples were collected over the course of one or two days in the living room of a fourth-floor apartment in New York City. Three types of samplers, the two aforementioned personal samplers and a high-flow rate pump (4 liters per minute), were operated side by side, and three samples of each type were collected during each sampling period. Intrasampler agreement as measured by relative standard deviation (RSD) was within 1% to 18%. After background subtraction, total PAH measured by all three sampler types had good agreement (R=0.99). This ability to accurately characterize personal PAH exposure in archived filters collected by these real-time samplers could provide additional important PAH exposure information that can benefit many environmental health studies using these monitors.

Keywords: Ionization; Pollutants; Chromatograph; Organic compounds; Mass spectrometry

Citation: Yan B, Pitiranggon M, Ross J, Arthen-Engeland T, Stelter A, et al. (2018) Validation of Miniaturized Particulate-Matter Real-Time Samplers for Characterizing Personal Polycyclic Aromatic Hydrocarbon Exposure. J Anal Bioanal Tech 9: 403. Doi: 10.4172/2155-9872.1000403

Copyright: © 2018 Yan B, et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Top