Evaluating the Effect of Economizer on Efficiency of the Fire Tube Steam Boiler
Received Date: Mar 14, 2018 / Accepted Date: Mar 24, 2018 / Published Date: Mar 27, 2018
Abstract
In this paper, the effects of using economizer on efficiency of examined fire tube steam boiler is presented. Based on the live tests, the performance indexes of two fire tube 3 passes wet back steam boilers with capacity of 3000 kg/h (one of them with economizer and another without economizer) measured. A MATLAB analysis with the comparison of different results is developed to evaluate the results produced by the live test. The indirect method is the applied method in this study, therefore various types of losses is measured. The results show the effect of using economizer for increase the feed water temperature and improving the efficiency of fire tube steam boiler.
Keywords: Fire tube boiler; Boiler efficiency; Economizer
Citation: Lahijani AM, Supeni EE (2018) Evaluating the Effect of Economizer on Efficiency of the Fire Tube Steam Boiler. Innov Ener Res 7: 193. Doi: 10.4172/2576-1463.1000193
Copyright: © 2018 Lahijani AM, et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Share This Article
Recommended Journals
Open Access Journals
Article Tools
Article Usage
- Total views: 10203
- [From(publication date): 0-2018 - Dec 18, 2024]
- Breakdown by view type
- HTML page views: 9264
- PDF downloads: 939