Noise Measurements and Sources of Noise in Primary Schools Located in Vulnerable Areas in Greece: A Cross-Sectional Study
Received: 29-Jun-2018 / Accepted Date: 19-Jul-2018 / Published Date: 26-Jul-2018 DOI: 10.4172/2329-6879.1000277
Keywords: Noise; Primary school; Education; Questionnaire; Greece
Introduction
Grade school is the cornerstone educational institution for children and adolescents. In addition, almost 75% of a typical school day is comprised of listening activities [1]. During the educational process, however, pupils and teachers are exposed to noise whose source may be from inside or from outside the classroom and/or the school. Furthermore, contemporary teaching methods that are founded on cooperative norms burden the educational process with additional noise [2].
It is well known that exposure to environmental and occupational noises is associated with impaired hearing, sleep disorders, cardiovascular disease, mental disorders, annoyance, interventions in communication, social relationship problems, and reduced work performance [3-5]. Additionally, there is a vast amount of literature linking increased noise levels with a series of effects on students during the educational process. These include, but are not limited to, decreased ability to recognize and comprehend verbal communication, inability to concentrate, decreased memory, and low school performance [6-8]. Long-term consequences include negative effects in pre-reading and reading abilities of children, which might be irreversible [8]. Children are more susceptible to the negative effects of elevated noise in school performance, which is attributed to factors related to the maturing of the hearing process, as well as to the fact that basic cognitive functions, like attention and memory, are less automated and more prone to disturbances [8,9]. Furthermore, teachers working in noisy classrooms are forced to constantly raise their voices in order to be heard and understood. This can be associated with vocal fatigue and other vocal dysfunctions [10].
Taking research findings into account, the World Health Organization (WHO) and other state institutions worldwide have adopted guidelines on setting noise limits of classrooms and other areas of the school in order to ensure the utmost efficiency of the educational process, as well as the vocal health of teachers [6].
In the present study, noise levels recorded in primary public schools located in areas of low socio-economic status (SES) within the prefecture of Attica, Greece.
In particular the aims of the study are:
Recording of the noise conditions prevailing in schools of socioeconomically vulnerable areas in the prefecture of Attica in Greece.
Evaluation of the recorded noise measurements through comparison with the guidelines set by WHO. Identification of the main noise sources which affect school classrooms through a survey addressed to school principals.
Materials and Methods
Study design
Recording, measurement, assessment, and analysis of noise levels in classrooms took place in public elementary schools located in the prefecture of Attica. These schools were enrolled in the DIATROFI program during the 2016-2017 school year. DIATROFI supports pupils of public schools that reside in socio-economically vulnerable areas of Greece and helps contribute to the reduction of food insecurity and obesity levels among school children. In particular, the program provides food-aid through the distribution of a free, nutritious, and daily meal to all students in participating schools, while at the same time promoting healthy eating through educational material and activities geared toward both students and their families. The DIATROFI Program has been implemented by the Institute of Preventive Medicine Environmental and Occupational Health, Prolepsis, since 2012, and it is executed under the auspices of the Ministry of Education, Research and Religious Affairs. The selection of schools participating in the program is based on food insecurity scores at the school level and along other socio-economic criteria.
The current study was conducted in 12 schools participating in the program, which were selected in order to cover a wide range of different noise settings, which is represented by the number of enrolled students and the age of the buildings. In total, noise measurements were conducted in 91 classrooms of all grades, 12 school yards, and outdoors at 9 schools.
Noise measurements
Recording, measurement, assessment, and analysis of noise levels in classrooms took place in public elementary schools. Noise measurements were conducted by specialized personnel of the Hellenic Institute for Occupational Health and Safety (HIOHS) with the use of a Bruel and Kjaer 2231 Sound Level Meter. Measurements were taken in May 2017, recording noise levels of empty classrooms, occupied classrooms during teaching, schoolyards, and outside of the school premises. Measurements were conducted during school operation times and were completed within one working day for each school. Each measurement was taken over a period of five minutes. A five minute noise sample in school environments is considered to be satisfactory, even for occupied classrooms [11,12]. For each condition/ location (unoccupied/occupied classroom, school yard, outside of school premises), the following measurements were recorded: the Aweighted equivalent continuous sound level (LAeq), the A-weighted noise level just exceeded for 10% of the measurement period (LA10), the A-weighted noise level just exceeded for 90% of the measurement period (LA90), and the A-weighted maximum and minimum sound levels (LAmax and LAmin respectively). An approximation of Signal to Noise Ratio (SNR) was calculated as Lesson Noise-Occupied Background Noise Level (OBNL) [13]. Depending on whether the measurement referred to an unoccupied or occupied classroom, we use the descriptions Unoccupied Ambient Noise Level (UANL LAeq including noise from other teaching areas of the school), Occupied Background Noise Level (OBNL LAeq90, occupied classroom), Lesson Noise, etc. All terms were derived from Shield et al. [14]. As, to our knowledge, there is no universally accepted and standardized method for recording noise level in schools [7,15], the procedure in the present study was selected in order to obtain the best possible capture of the noise conditions prevailing in Greek classrooms.
Unoccupied classrooms noise measurement
Measurements were taken in an empty classroom, while pupils were having class elsewhere, and during normal school operation (thus, other school facilities were in normal use, not during break time) as suggested by Shield and Dockrell [7]. Doors of the classrooms were kept closed when measurements were being taken. However, ventilation and cooling needs require, most of the time, the windows to be kept open. Therefore, it was chosen for the windows to be in their usual state according to the wishes of teachers and students. In the vast majority of recorded classrooms, the windows were kept open. The sound level meter was mounted on a special base (tripod 1.55 cm height) at the front of the room and at least a meter away from the walls and the door. In addition to sound levels, the volumes of the classrooms (in m3) were also recorded.
Noise measurements during class
For each classroom, noise measurements were taken when the classroom was in use and at a separate time in the same classroom when empty. During the measurements of both the occupied and unoccupied classrooms, the doors were kept closed and the windows were left in their usual positions, as previously described. The sound meter was located at a point in the room that caused the least possible obstruction in the teaching process, at least a meter away from the nearest wall and away from the teacher's direct sound field.
Noise measurements in the schoolyard
In the schoolyard of the schools, measurements were taken during class time (not during break time). Regardless, there were always students present in the schoolyard, who did gymnastics in the presence of a trainer.
Outdoors noise measurements
Outdoor measurements took place adjacent to the school building side that was determined to have the highest burden of environmental noises. The estimation was an outcome of the researcher’s observation.
Criteria for evaluation of recorded noise measurements
Measurements conducted are compared with the World Health Organization’s (WHO) guidelines for maximum noise levels in schools [3]. These guidelines suggest a maximum of 35 dB for UANL (Laeq dB) in the classroom and a maximum of 55 dB for outdoor playgrounds. The UANL(Laeq dB) level of 35 dB (A) LAeq is established assuming a level of 55 dB (A) for a teacher's voice at a one meter distance combined with the need for a signal to noise ratio of at least 15 dB. The maximum noise level of 55 dB (A) in outdoor playgrounds was chosen to be the same as those for outdoor residential areas in the daytime, in order to prevent noise annoyance [6].
Taking into account the developmental differences that have been identified to the extent that noise affects learning, some researchers propose separate noise and SNR limits, both changing per age group of students [2,16,17]. In the context of the present study, the measured sound/noise was also compared with the acoustic recommendations for primary school classrooms proposed by mealing, et al. (Table 1) [2].
Age Group | Rating | UANL(LΑeq dB) | OBNL(LA90 dB) | SNR |
---|---|---|---|---|
6-7 years | Good | <28 | < 45 | +20 dB |
OK | 28-35 | 45-50 | +15 to +20 dB | |
Bad | >35 | >50 | <+15 | |
8-9 years | Good | <35 | <47 | >+18 |
OK | 35-40 | 47-53 | +12 to +18 | |
Bad | >40 | >53 | <+12 | |
10-11 years | Good | <39 | <50 | >+15 |
OK | 39-40 | 50-56 | +9 to +15 | |
Bad | >40 | >56 | <+9 | |
12+ years | Good | <40 | <50 | >+15 |
OK | 40-45 | 50-56 | +9 to +15 | |
Bad | >45 | >56 | <+9 | |
Overall | Good | <30 dBA | <50 dBA | >+15 dB |
OK | 30-40 dBA | 50-55 dBA | +10 to +15 dB | |
Bad | > 40 dBA | >55 dBA | <+10 dB |
Table 1: Overall acoustic evaluation of classrooms by age of students according to Mealing 2016.
School principal’s questionnaire
Characteristics of the schools and classrooms that are possibly associated with noise levels were recorded through a questionnaire that was filled in by the schools’ principals. Such characteristics included whether the school was close to an avenue/central road, whether the classroom had windows facing such a road, whether the classroom was prefabricated, etc.
In the same questionnaires, the principals’ opinions concerning the degree at which several noise sources affect the educational process were recorded, separately for each classroom. Noise sources that were assessed included pupils themselves, car and train traffic, noises originating from people outside the school compound and noises originating from teaching in other classrooms. These sources were assessed with a 5-grade scale, where 1 indicated an effect on the educational process as “not at all” and 5 as “to a great degree”
Limitations of the Study
Despite the important role it plays in the acoustics of the classrooms, the reverberation time was not recorded in the context of the present study, while the Signal to Noise Ratio (SNR) index was estimated as already described (i.e. Lesson noise-OBNL) [13]. In addition, the fact that the activities of teachers and students were not recorded during the measurement of the lesson noise constitutes another limitation of the study.
Results
Noise measurements
Table 2 shows the basic characteristics of the schools included in the sample. Total number of students ranges from 90 to 306 and the average number of students per classroom from 11 to 21. Half (6) of the schools are located in a distance of less than 100 meters from a main road, while four are closer than 100 meters to a traffic light. Only two schools were located close to an airport.
School | Area | No. of students | Average No of students per classroom | Age of the building | Distance of main road less than 100 m (Yes-No) | Distance of traffic lights less than 100 m (Yes-No) | Close to Airport (Yes-No) | No of classrooms measured |
---|---|---|---|---|---|---|---|---|
1 | Athens Center | 123 | 21 | 121 | Y | Y | N | 6 |
2 | Athens Center | 92 | 15 | 86 | N | N | N | 6 |
3 | Ano Liosia | 190 | 19 | 33 | Y | N | N | 7 |
4 | Athens Center | 90 | 15 | 33 | N | N | N | 7 |
5 | Aspropirgos (Industrial area) | 193 | 19 | 14 | N | N | Y | 7 |
6 | Athens Center | 175 | NA | 15 | Y | Y | N | 9 |
7 | Athens Center | 164 | 21 | 88 | Y | Y | N | 7 |
8 | Aspropirgos (Industrial area) | 306 | 21 | 28 | N | N | N | 9 |
9 | Aspropirgos | 293 | NA | NA | N | N | Y | 10 |
10 | Zefiri | 226 | 19 | 28 | Y | N | N | 8 |
11 | Athens Center | 95 | 11 | 68 | Y | Y | N | 7 |
12 | Asprorirgos (Industrial area) | 201 | 17 | 28 | N | N | N | 8 |
Table 2: Characteristics of schools surveyed.
Average recorded noise measurements per school are presented in Table 3. Because measurements were taken in May and no schools (except for school 11) had air-conditioning in operation, windows were often left open during the recording of noise level. School 11, despite being close to a main road with a significant amount of external noise (71.7 LAeq dB), exhibited the lowest average UANL (52.6 LAeq dB). It should be noted that in Greece, and especially in the prefecture of Attica, classroom windows are open most of the time throughout the school year for ventilation purposes.
School | UANL(LAeq dB) | OBNL(LA90 dB) | Lesson Noise LAeq dB (occupied) | SNR (Estimated) | School Yard Noise (LAeq dB) | School Yard Backround Noise (LA90 dB) | External Noise Level LAeq dB |
---|---|---|---|---|---|---|---|
1 | 56.2 (5.4) |
56.3 (3.4) |
71.3 (3.4) |
14.9 (4.2) |
70.9 | 59 | 68.7 |
2 | 54.5 (2.4) |
54.8 (7.9) |
66.3 (8) |
11.5 (2.3) |
80.9 | 72 | 69.5 |
3 | 56.2 (6.3) |
58.6 (5.7) |
75 (4.7) |
16.4 (3.4) |
71.9 | 57 | NA |
4 | 59.4 (6) |
55.2 (8.6) |
70.5 (8.6) |
15.1 (2.1) |
77.4 | 62.5 | 65.6 |
5 | 56.6 (8.9) |
53.9 (6.9) |
69 (5.9) |
15.1 (2.1) |
74 | 60 | 63.9 |
6 | 58.1 (5.1) |
54.3 (4.1) |
69.3 (4.5) |
15.1 (4.5) |
62.8 | 53 | 70.3 |
7 | 58 (2.3) |
55.8 (6.3) |
69.2 (5.9) |
13.4 (2.5) |
78 | 70.5 | 72.2 |
8 | 59.4 (3.6) |
60.6 (5) |
75.5 (5.6) |
15 (3.3) |
83 | 70 | NA |
9 | 58.3 (5.4) |
56.1 (6.6) |
69.7 (7.3) |
13.7 (2.1) |
84.5 | 78 | 62.4 |
10 | 55.2 (4.2) |
55.9 (6.8) |
70.4 (9.4) |
14.5 (3.8) |
84.5 | 66 | 61.2 |
11 | 52.6 (2.6) |
54.9 (8.5) |
67.4 (11) |
12.5 (5.2) |
84.4 | 79 | 71.7 |
12 | 57.9 (6.3) |
51.2 (3.6) |
67.1 (5.8) |
15.9 (3.8) |
71 | 60 | NA |
Mean (all classrooms) | 57 (5.2) |
55.7 (6.2) |
70.1 (7.1) |
14.5 (3.5) |
77.1 (6.6) |
65.6 (8) |
66.6 (3.9) |
Table 3: Average Noise Level Measurements per school surveyed and standard deviation (sd).
All (100%) measurements of both UANL and school yards were higher than the WHO recommended maximum levels. School yard background noise was of acceptable levels in only one school. According to the overall criteria set by Mealing (2016) [2], all (100%) classrooms were classified as “Bad” concerning UANL and OBNL, while 45 classrooms (52.3%) were classified as “OK” and the remaining 41 (47.7%) classified as “Bad” for SNR. When the assessment is broken down by student age and the respective relevant classification, UANL is still “Bad” for all classrooms in all age groups (Table 4). However, there is a significant association between age group and both OBNL (p=0.001) and SNR (p=0.003). Specifically, classrooms of older pupils are more often classified as “Good” or “OK” for OBNL. For SNR, while no classrooms are classified as “Good”, the proportion of “Bad” in classrooms of younger pupils is considerably higher than that of older pupils.
Age Group | Rating | UANL(LΑeq dB) | OBNL(LAeq90 dB) | SNR | |||
---|---|---|---|---|---|---|---|
Number of Classrooms | % | Number of Classrooms | % | Number of Classrooms | % | ||
6-7 years | Good | 0 | 0 | 0 | |||
OK | 0 | 3 | 12.50 | 6 | 25 | ||
Bad | 24 | 100 | 21 | 87.50 | 18 | 75 | |
8-9 years | Good | 0 | 2 | 6.70 | 0 | ||
OK | 0 | 11 | 36.70 | 21 | 70 | ||
Bad | 30 | 100 | 17 | 56.70 | 9 | 30 | |
10-11 years | Good | 0 | 6 | 18.80 | 0 | ||
OK | 0 | 15 | 46.90 | 19 | 59.40 | ||
Bad | 32 (100) | 100 | 11 | 34.40 | 13 | 40.6 | |
p-value | 1 | 0.001 | 0.003 |
Table 4: Acoustic evaluation of surveyed classrooms (excluding computer labs) according to criteria set by Mealings 2016.
Table 5 shows the average noise measurements in classrooms with characteristics that could potentially affect the level of noise recorded. It is evident that both the presence of a window facing a main road and a prefabricated (prefab) classroom are associated with higher average noise measurements. OBNL and Lesson Noise were both significantly higher in classrooms with a window to a main road (p=0.04 and p=0.03 respectively). Finally, a significant correlation has been identified between UANL and Lesson noise (ρ=0.28, p=0.01) (Figure 1).
UANL(LAeq dB) | OBNL(LAeq90 dB) | Lesson Noise LAeq dB (occupied) | SNR (Estimated) | |
---|---|---|---|---|
Classrooms with window towards avenue or main road | 58.2 | 58.1 | 73.1 | 15 |
(st. dev.) | (4.4) | (5.5) | (5.3) | (4.1) |
Classrooms with no window towards avenue or main road | 56.7 | 55 | 69.4 | 14.3 |
(st. dev.) | (5.4) | (6.3) | (7.3) | (3.4) |
Prefab classrooms | 58.2 | 56.7 | 72 | 15.4 |
(st. dev.) | (5.3) | (6.6) | (7.3) | (3.4) |
Non Prefab classrooms | 56.7 | 55.4 | 69.6 | 14.2 |
(st. dev.) | (5.2) | (6.2) | (7) | (3.5) |
All Classrooms | 57 | 55.7 | 70.1 | 14.5 |
(st. dev.) | (5.2) | (6.2) | (7.1) | (3.5) |
Table 5: Average Accoustic Measurments by type of classrooms.
The main findings of the study are presented in comparison with the findings of studies carried out in other countries in Table 6.
Measurements in Athens | Measurements in London [7] | Measurements in Edinburgh [19] | Measurements in Brazil [18] | |
---|---|---|---|---|
External noise measurements | 61.2 – 72.2 LAeq dB 66.6 (Mean) |
31 - 78 LAeq dB 57.4 (Mean) |
||
Classroom noise measurement Unoccupied Background Noise Level (UBNL) |
44.9 – 68.1 LAeq dB 57 (Mean) |
47 LAeq dB (Mean) | Classrooms with no acoustical treatment (mean): 55.5 LAeq dB Classrooms with acoustical treatment (mean): 46.5 LAeq dB |
51.5-70.5 LAeq dB |
Table 6: Comparison of noise measurements with findings from similar studies in other countries.
Of particular interest is the fact that both prefab classrooms and classrooms with a window facing an avenue or a main road were more overburdened by the different forms of noise than average (Figure 3 and Figure 4). Specifically, 27.8% of both these categories of classrooms were influenced to a “large” or “very large” extent by car traffic; whereas, as mentioned above, the proportion for all classrooms participating in the survey was only 9.3%. Noise coming from people speaking outside the school building does not seem to significantly affect classrooms with a window at a main road, while teaching in other areas of the school was judged to affect teaching to a “great”/ “very great” degree in 100% of prefab halls and in 44.4% of classrooms with a window on an avenue or main road. In both prefab and window-classrooms, students themselves seem to be a particularly important source of noise, since they seem to affect teaching, to a “large” or “very large” extent, in about half of these classrooms.
Discussion
As demonstrated by the results, the schools involved in the study are particularly burdened by noise in both classrooms and courtyards. Additionally, particularly high noise levels were captured outside the school buildings.
In particular, the recorded noise level outside the school premises is quite high compared to what was recorded in London for primary and secondary school premises [7,17]. Specifically, the average external noise level in the 9 surveyed schools in Attica was 66.6 LAeq dB, while in London the corresponding measurement for primary schools was 57.4 LAeq and for secondary schools 52.07 LAeq dB. According to the above finding, the schools that participated in the survey are particularly exposed to environmental noise. Noise measurements of both UANL and school yards in all classrooms exceed WHO guidelines for maximum levels. In particular, all (100%) measurements of both were higher than the WHO recommended maximum levels. According to the overall criteria set by Mealing [2], in an attempt to bring together acoustic standards and recommendations as well as noise levels measured in classrooms across the world, all (100%) classrooms were classified as “Bad” concerning UANL and OBNL. 45 classrooms (52.3%) were classified as “OK” for SNR, with the remaining 41 (47.7%) being termed “Bad” for the same measure. In addition, by differentiating the acoustic environment that pupils of different ages require because of developmental differences, the proportion of acceptable (but not ideal) classrooms, in terms of both OBNL and SNR, increases with the age of students. Although, UANL measurements are still “Bad” for all classrooms. In the majority of similar surveys conducted in different parts of the world, however, the noise levels recorded in the classrooms most of the time exceed the proposed limits. In our case, both the average level of Lesson Noise (70.1 LAeqdB) and the OBNL (55.7) are quite close to what is recorded in similar research done in different parts of the world. For example, in a study conducted in London [7], the average OBNL recorded was 54.1 LAeq90 dB, while lesson noise was 72.1 LAeq dB. What appears to be particularly elevated for enclosed classrooms, in the case of our schools, is UANL (57 LAeq dB), with a corresponding measurement in the Shield and Dockrell survey of 47 LAeq dB. Similar UANL levels were recorded in Brazil [18] with a UANL level of 51.5-70.5 LAeq dB. Also, in Edinburgh in 1998, a mean UANL of 55.5 LAeq dB was measured in classrooms that had not undergone acoustic improvements, while, in classrooms that had, the UANL was 46.5 [19] (For a review, see Mealing [2]).
Meanwhile, the significant correlation that has been identified between UANL and Lesson noise (ρ=0.28, p=0.01) is a possible manifestation of the Lombard effect, as noisier empty classrooms seem to be noisier during lesson time as well (Figure 1). In particular, the “Lombard effect” describes the speaker's tension to increase their voice level when background noise exists. More specifically as it pertains to classrooms, as the background noise level increases, the voice intensities of both the teacher and the students participating in lesson activities tend to increase too. This is a result of an effort to improve the audibility and communication potential. Meanwhile, students who, for any reason, talk to each other about issues irrelevant to the lesson, have to speak louder in order to be heard by their seatmate, charging the auditory environment of the classroom even more. [20].
The regression line fitted (y=48.81+0.37x) suggests that the expected value of lesson noise in a classroom with UANL of 35 dB (WHO limit) is 61.8 LAeq dB, significantly lower than the recorded average lesson noise level 70.1 LAeq dB. It should be noted that all the above acoustic guidelines refer to children without any specific needs. In cases of children with hearing impairments or language delays, proposed limits are even more challenging.
Concerning classroom characteristics, both the presence of a window facing a main road or an avenue and of a prefab classroom produce higher average noise measurements. Βoth OBNL and Lesson noise were significantly higher in classrooms with a window to a main road or an avenue (p=0.04 and p=0.03 respectively).
According to school principals, teaching in other areas of the school is the main source of noise in the classrooms that participated in the study, followed by students within the classrooms themselves, people talking outside the building, and traffic. Traffic noise and noise from teaching in other areas affect, to a higher degree, both classrooms with windows facing an avenue or a main road and prefab classrooms. Teaching that takes place in other areas affects, to a “large” or “very large” degree, all prefab classrooms. Of particular interest is the fact that, in both prefab classrooms and classrooms with window facing avenue or main road, students themselves become a particularly important source of noise, as they seem to affect teaching to a “large” or “very large” extent, in about half of these classrooms. This finding, combined with the fact that these classrooms are more exposed and burdened by other environmental noises, is another possible confirmation of the Lombard effect.
In conclusion, the noise levels recorded in both schoolyards of schools and classrooms are considerably higher than the proposed limits of WHO and of other national guidelines across the world. The particularly high level of UABL noise recorded in all classrooms can be attributed to poor sound insulation-especially in the prefab classrooms-in conjunction with the fact that windows in the majority of the classrooms were open for cooling and ventilation purposes during measurement. It is a worthwhile finding that the lowest average UANL level (52.6 LAeq dB) was recorded in a school whose classrooms had air conditioning, and, therefore, the windows were closed during measurement. According to school principals, the most important source of noise for the classrooms is teaching in other areas of the school. Traffic becomes an important source of noise in both prefab classrooms and classrooms with windows on avenue or main road. At the same time, higher average noise measurements were recorded in the classrooms with these specific characteristics, as “students themselves” appeared to become a serious source of noise. This finding could be attributed to Lombard effect as, in addition, a significant correlation between lesson noise and UANL has been identified at total classrooms level.
Nowadays, it is extremely difficult for school buildings in Greece to be properly maintained or to adapt to changes occurring in their external environment through intervention, due to economic crisis and budget constraints. Most of the buildings remain as they were several decades ago, while the environment in which they are located changes drastically.
However, the serious impact of noise on the health of both students and teachers as well as on the education and cognitive development of students, must be taken seriously into consideration in order to determine the necessary interventions to implement for improving the acoustic environment of schools. Particularly for the socioeconomicallyvulnerable areas of the country, the unfavorable listening conditions captured in primary schools should be considered in the context of a holistic approach that takes into account the accumulation of other risk factors in noise-exposed children.
Here are some suggestions for interventions that seem appropriate to schools that participated in the study:
Replacement of all prefabricated classrooms/schools, which has remained in function for many years due to budget restrictions, although they only should have been used as a temporary solution.
Examine the possibility of changing the ventilation/air conditioning mode (not through open windows) and installing low noise ventilation/air conditioning devices. In this case, the change of windows to double glazing should also be considered for better sound insulation.
For schools located on or near main roads, that cannot be moved in the context of current financial circumstances, consideration should be given to the possibility of restructuring car circulation during school operation. Installations of noise barriers and/or tree planting are some alternative solutions. Reorganization of the school premises, so that the classrooms are located in the "quiet parts" of the premises, could be another possible solution.
Regarding the interventions that should be made inside the classrooms, it is known that the basic principles of sound architecture necessitate that every space has its own requirements and therefore needs special design. Some materials, for example, are ideal for absorbing low frequency noise, such as traffic noise. Other materials are better at absorbing noise of higher frequency, such as children's voices. In general, it is common practice for sound absorbers to be placed on the ceiling of classrooms, while sound diffusers are placed on the walls. Enriching the furniture of the classroom is another common intervention in schools that improves acoustics.
Roughly speaking, the average cost for the acoustical treatment of classrooms including internal interventions, installation of ventilation/air conditioning systems, and change of windows to double glazing is 10% of the cost of building a new school—or approximately 100 € per square meter.
References
- Dahlquist LH (1998) Classroom amplification: Not just for the hearing impaired anymore. Presented at the CSUN, Los Angeles, California.
- Mealings K (2016) Classroom acoustic conditions: Understanding what is suitable through a review of national and international standards, recommendations, and live classroom measurements. Presented at the second australasian acoustical societie’s conference, Brisbane.
- Berglund B, Lindvall T, and Schwela DH (1999) Guidelines for community noise. World Health Organization.
- Vermeer WP, Passchier WF (2000) Noise exposure and public health. Environ Health Perspect 108: 123–131
- Goines L and Hagler L (2007) Noise pollution: A modem plague. South Med J 100: 287–294.
- Shield B and Dockrell J (2003) The effects of noise on children at school: A review. Building Acoustics 10: 97–106.
- Shield B and Dockrell JE (2004) External and internal noise surveys of London primary schools. J Acoust Soc Am 115: 730–738.
- Klatte M, Bergstroem K, and Lachmann T (2013) Does noise affect learning? A short review on noise effects on cognitive performance in children. Front Psychol 4.
- Werner LA (2007) Issues in human auditory development. J Commun Disord 40: 275–283.
- Kristiansen J, Lund SP, Persson R, Challi R, Lindskov JM, et al. (2015) The effects of acoustical refurbishment of classrooms on teachers’ perceived noise exposure and noise-related health symptoms. Int Arch Occup Environ Health 89: 341–350.
- https://www.environmental-expert.com/articles/links-between-noise-and-air-pollution-and-socioeconomic-status-673785
- Puglisi G, Astolfi A, Cutiva LC, and Carullo A (2015) Assessment of indoor ambient noise level in school classrooms. Presented at the Euronoise 2015, Maastricht, The Netherlands.
- Canning AJD (2012) The Essex Study: Optimised classroom acoustics for all. Association of Noise Consultants, St. Albans, Hertfordshire, UK.
- Shield B, Conetta R, Dockrell J, Connolly D, Cox T, et al. (2015) A survey of acoustic conditions and noise levels in secondary school classrooms in England. J Acoust Soc Am 137: 177–188.
- Fidêncio VLD, Moret ALM, de Jacob RTS, Fidêncio VLD, Moret ALM, et. al. (2014) Measuring noise in classrooms: a systematic review. CoDAS 26: 155–158.
- Bradley JS, Sato H (2008) The intelligibility of speech in elementary school classrooms. J Acoust Soc Am 123: 2078–2086.
- Picard M, Bradley JS (2001) Revisiting speech interference in classrooms. Audiol Off Organ Int Soc Audiol 40: 221–244.
- Losso M, Viveiros E, Figueiredo T (2004) An overview of acoustical features in brazilian school buildings. In The 33rd International Congress and Exposition on Noise Control Engineering, Prague.
- Airey S (1998) A survey of acoustical standards in UK classrooms and their effect on pupils and teachers. In Inst Acoustics London.
- Junqua JC (1996) The influence of acoustics on speech production: A noise-induced stress phenomenon known as the Lombard reflex. Speech Commun 20: 13–22.
Citation: Kapetanaki S, Konstantopoulou S, Linos A (2018) Noise Measurements and Sources of Noise in Primary Schools Located in Vulnerable Areas in Greece: A Cross-Sectional Study. Occup Med Health Aff 6: 277. DOI: 10.4172/2329-6879.1000277
Copyright: © 2018 Kapetanaki S, et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Share This Article
Recommended Journals
Open Access Journals
Article Tools
Article Usage
- Total views: 6236
- [From(publication date): 0-2018 - Dec 12, 2024]
- Breakdown by view type
- HTML page views: 5477
- PDF downloads: 759