Make the best use of Scientific Research and information from our 700+ peer reviewed, Open Access Journals that operates with the help of 50,000+ Editorial Board Members and esteemed reviewers and 1000+ Scientific associations in Medical, Clinical, Pharmaceutical, Engineering, Technology and Management Fields.
Meet Inspiring Speakers and Experts at our 3000+ Global Conferenceseries Events with over 600+ Conferences, 1200+ Symposiums and 1200+ Workshops on Medical, Pharma, Engineering, Science, Technology and Business

Image-Derived Blood Input Function from FDG-PET Images in Mice

Min Zhong1,2 and Bijoy Kundu2,3*
1Department of Physics, University of Virginia, Charlottesville, VA, USA
2Department of Radiology and Medical Imaging, University of Virginia, Charlottesville, VA, USA
3Cardiovascular Research Center, University of Virginia, Charlottesville, VA, USA
Corresponding Author : Bijoy Kundu
Department of Radiology and Medical Imaging
University of Virginia, Charlottesville, VA, USA
Tel: (434) 924-0284
Fax: (434) 924-9435
E-mail: bkk5a@virginia.edu
Received February 17, 2012; Accepted February 17, 2012; Published February 19, 2012
Citation: Zhong M, Kundu B (2012) Image-Derived Blood Input Function from FDG-PET Images in Mice. Radiol Open Access. 1:e103. doi: 10.4172/2167-7964.1000e103
Copyright: © 2012 Zhong M et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Visit for more related articles at Journal of Radiology

Abstract

  

Editorial
In a dynamic Positron Emission Tomography (PET) scan, the blood pool (BP) time activity curve forms the input function in a compartmental model technique for evaluation of rate constants to measure myocardial glucose uptake and utilization in vivo. Several methods have been described in the literature for arterial blood sampling, which is the accepted gold standard for measurement of the blood input function [1-3]. A major problem with image-derived blood input function (IDIF) method is that it is susceptible to Spillover (SP) and Partial Volume (PV) effects more so at the early time points due to rapid metabolism and also at the late time points due to cellular trapping of 2-[18F] fluoro-2deoxy-D-glucose (FDG) .
In a recent publication from our lab [4], we obtained an imagederived blood input function (IDIF) from cardiac gated Ordered Set Expectation Maximization-Maximum a Posteriori (OSEMMAP) reconstructed images with attenuation correction in a control mouse heart with no further SP correction. The PV coefficient was incorporated as an input parameter from phantom experiments. Although this method may work in a control mouse heart due to reduced SP contamination into the LVBP from the myocardium and vice-versa, SP contamination will be more severe in diseased hearts especially at the early time points, in a changing metabolic environment [5] in a dynamic PET scan. Also, it is non-trivial to account for PV coefficients with changing cardiac dimensions in a changing metabolic milieu.
In a recent work [6], we optimized a compartment model corrected blood input function (MCBIF) [7] in vivo in mouse hearts, wherein the blood input function with SP and PV corrections and the metabolic rate constants in a compartment model were simultaneously estimated from OSEM-MAP cardiac and respiratory gated PET images with attenuation correction. This technique not only improves quantitation but is also repetitive. From an imaging perspective accurate quantitation of the blood input function in vivo will reduce animal handling during imaging and provide reliable estimates of the kinetic parameters needed for accurate computation of metabolic influx constants. The unique advantage of this multiparameter approach is that no apriori knowledge of the cardiac dimensions is needed. The proposed imaging technique [6] correctly takes into account PV and SP corrections, for both the LV and the myocardium, in a changing metabolic milieu by optimizing to the blood and tissue time activity curves obtained from high resolution gated and attenuation corrected dynamic PET images, without the need for any additional blood sampling.
Absolute quantification of the blood input function and thereby absolute myocardial metabolic activity in vivo is important especially in a changing metabolic environment with changing cardiac dimensions during the progression and the regression of a disease, for example, in a surgical mouse model of Transverse Aortic Constriction induced Left Ventricular Hypertrophy (LVH), to differentiate diseased hearts from controls [5]. From a clinical standpoint, this technique is important since quantification of absolute metabolic activity can differentiate which patients are going to develop LVH or heart failure with a single measurement.
Acknowledgements
The work in this editorial was supported by NIH grant R21 HL 102627 (to BK).