ISSN: 2469-9764
Industrial Chemistry
Make the best use of Scientific Research and information from our 700+ peer reviewed, Open Access Journals that operates with the help of 50,000+ Editorial Board Members and esteemed reviewers and 1000+ Scientific associations in Medical, Clinical, Pharmaceutical, Engineering, Technology and Management Fields.

Control of Corrosion and Microbial Corrosion of Steel Pipelines in Salty Environment by Polyacrylamide

El-Shamy AM1*, Zohdy KM2 and El-Dahan HA1

1Physical Chemistry Department, Electrochemistry and Corrosion Laboratory, National Research Centre, El-Bohouth St. 33, Dokki, PO 12622, Giza, Egypt

2Higher Technological Institute, 10th of Ramadan City, Egypt

*Corresponding Author:
El-Shamy AM
Physical Chemistry Department Electrochemistry
and Corrosion Laboratory National Research Centre
El- Bohouth St. 33 Dokki, PO 12622, Giza, Egypt
E-mail: elshamy10@yahoo.com

Received date: April 07, 2016; Accepted date: April 27, 2016; Published date: April 29, 2016

Citation: El-Shamy AM, Zohdy KM, El-Dahan HA (2016) Control of Corrosion and Microbial Corrosion of Steel Pipelines in Salty Environment by Polyacrylamide. Ind Chem 2:120. doi: 10.4172/2469-9764.1000120

Copyright: © 2016 El-Shamy AM, et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Visit for more related articles at Industrial Chemistry

Abstract

The polyacrylamide was investigated for controlling of corrosion and microbial corrosion of mild steel in salty media. Both the corrosion inhibition efficiency and biocidal activity are measured at different concentrations of polyacrylamide. The electrochemical measurements are used to monitor the corrosion results and the serial dilution method is used to detect the biocidal activity. The results showed that the polyacrylamide is improved the biocidal activity corrosion resistance for mild steel with increasing the concentration. The biocidal activity was subjected to the planktonic and sessile bacteria and the obtained results proved that the killing effect of polyacrylamide is shows higher efficiency in planketoinc more than the sessile bacteria. The corrosion data proved that, the inhibitor shows acceptable effect against corrosion in chloride solution and the effect is also depends on the inhibitor concentration. The best result in both corrosion and microbial corrosion is obtained at concentration of 15 ppm.

Keywords

Biocidal activity; Mild steel; Corrosion; Electrochemical techniques; Polyacrylamide

Introduction

One of the main factors of metal deterioration is microbial corrosion and it is well identified in the most recent papers as the main reason of pipeline failure in sulfide and chloride media [1-5]. There are many types of microorganisms are involved in the microbial corrosion and responsible for corrosion failure of mild steel, stainless steel and as well as copper and its alloys. Sulfate reducing bacteria id considered one of the well-known anaerobic bacteria that have the ability to attack the metals and its alloys [5-10]. The attack of sulfate reducing bacteria (SRB) is very easy detectable by forming iron sulfide FeS with black film. The microbial corrosion starts with the formation of biofilm from the aerobic bacteria and then the underneath of biofilm the anaerobic bacteria starts to grow and in the same time the localized corrosion is start its work [11]. The galvanic corrosion is also starts due to the formation of oxygen concentration cell because the concentration of oxygen underneath biofilm is lower than that in the external part. There are many other kinds of corrosion are starts to work as a result of microbial corrosion as crevice corrosion, and selective de-alloying. The microbial corrosion not only occurs under anaerobic condition but also at aerobic conditions. The presence of aerobic bacteria initiates the general corrosion through the formation of metal oxide by the presence of metal oxidizing bacteria. The hydrogen sulfide is produced as a result of metabolism of sulfate reducing bacteria by reduction of sulfur compound [12,13]. The microbial corrosion could be controlled by using oxidizing and/or non-oxidizing biocides. By the way the oxidizing biocide became well known for all specialists in the field of microbial corrosion but the non-oxidizing still worked under license, so it is considered a very good task if we got a new available, safe and cheap compound for control the microbial growth by stopping the microbial growth of killing the anaerobic bacteria. The quaternary ammonium salts are used with higher efficiency of killing the bacteria especially anaerobic bacteria. There are many trials to investigate new organic compounds to be used as biocide for anaerobic bacteria [14]. It is very important to select biocide has considerable effect in low concentration and in the same time with environmental impact. The most abundant biocide in the field is quaternary ammonium salts because it shows highly effect with low concentration [15-17]. The killing effect of quaternary ammonium salts is occurred through its ability to diffuse through the cell wall of microorganisms and destroy the cytoplasmic membrane that causes cell death. Otherwise its toxicity is considered acceptable for a variety of uses specially in cooling water systems [18,19]. Some biocides are excluded because of its toxicity as organotin compounds, although it shows excellent killing effect in controlling the biofouling in marine environmental paints [20-23]. In the recent few years some trials are done for evaluation of some ionic liquids against microbial corrosion in cooling water [24-27]. This paper is aiming at assessment and investigation of the possibility of using polyacrylamide as biocide for general kinds of bacteria. The task is classified into three parts; the first one is concerned with the test against planketonic bacteria and the second part of research is test against sessile bacteria finally we will check the corrosion behavior at the recommended concentration of microbial activity. We predict to get promising results due to the highly reactive amide (NH2) group. Polyacrylamide can be chemically modified to produce both positively or negatively charged and this will produce cationic or anionic polymer, these properties gave polyacrylamide broad spectrum against varieties of microorganisms. There are many applications for polyacrylamide as in wastewater treatment, enhanced oil recovery, improve the economics of conventional water flooding, soil conditioner, gro-beast toys, additive in body-powder and molecular biology applications as a medium for electrophoresis of proteins and nucleic acids. Polyacrylamide used in agriculture may contaminate food with acrylamide, a known neurotoxin. While polyacrylamide itself is relatively non-toxic, it is known that commercially available [28-31].

Materials and Methods

Materials

Electrodes: Working electrode of mild steel electrode was used. The mild steel electrode was spherical shape sealed in epoxy with an exposed area of 0.785 cm2. The electrode was polished with fresh emery paper different grades till fine mirror surface, washed with acetone before immersion. The counter electrode was a platinum (Pt) wire. A saturated calomel electrode was used as reference electrode. A twocompartment glass cell holding 100 ml solution was used in the test involving mild steel. Solutions were prepared from doubly distilled water and analytical grade chemicals. Polyacrylamide was purchased from Fluka Chemicals.

Culture media: Postgate medium (B), gl−1 KH2PO4, 0.5; NH4Cl, 1.0; CaSO4, 1.0; MgSO4·7H2O, 2.0; sodium lactate, 3.5; yeast extract. 1.0; ascorbic acid. 0.1; thioglycolic acid, 0.1; FeSO4. 7H2O, 0.5. The pH 7.5. Postgate medium (E), gl−1 KH2PO4, 0.5; NH4Cl, 1.0; Na2SO4, 1.0; MgCl2·6H2O, 2.0; CaCl2·H2O, 1.0; sodium lactate, 3.5; yeast extract. 1.0; ascorbic acid. 0.1; thioglycolic acid, 0.1; FeSO4. 7H2O, 0.5; agar, 15.0 [32].

Methods

Antibacterial activity: Certain amount of salt water was subjected to circulation and the volume was established by adding distilled water to feed the vaporized water. Samples of circulated water were taken with time to monitor the microbial growth and this experiment is considered as the blank experiment. The recommended doses were added individuals to check the best one. These experiments are carried out for planketonc bacteria and in the same time we put coupon from mild steel in the circulated water to form the biofilm on its surface for the experiments of sessile bacteria. The water samples were detected for microbial growth by serial dilution method and turbidity in test tubes is used as a function of bacterial growth. A sterile safety razor is used for collecting the sessile bacteria included anaerobic and aerobic bacteria were developed from the surface of mild steel coupon which immersed in the circulating water. In a Postgate medium B inoculated with sessile bacteria for 7 days at 30°C.

Antibacterial effect of PAA: Gradual concentrations from 5 to 15 ppm of PAA were injected in cooling water and then samples were taken with period of time. After incubation time the data were collected and the bacterial growth inhibition has been estimated [33]. The sessile bacteria is scraped by sterile razor and collected in sterile test tubes containing 9 ml Postgate medium B to be treated as Planktonic ones to detect minimum inhibitory concentration (mic) of (PAA) against sessile and Planktonic bacteria.

Electrochemical measurements: Potentiodynamic polarization curves were measured on the mild steel electrode in 3.5% NaCl and PAA at a voltage scan rate of 1 mVs-1. Corrosion rates and inhibition efficiencies were determined. Electrochemical measurements were performed using Gamry Instrument potentiostat/galvanostat/ZRA, which included Gamry framework system based on the Ref 600. Gamry applications that include potentiodynamic scan and EIS are DC105 and EIS300 software. Measurements were performed at 25 ± 1°C while the electrolyte was stirred using a magnetic stirrer. The potentiodynamic current voltage characterization was recorded. A Gamry water-jacketed glass cell of capacity 175 ml was used which contained three electrodes for working, counter and reference electrodes. The electrode was immersed for 30 min in the test solution in free corrosion conditions before recording the polarization curves. After attaining steady open circuit potential (OCP) the polarization was started from about 100 mV more negative than OCP to about 200mV more positive than OCP, at a scan rate of 1 mVs-1. After this forward half cycle, the scan was reversed to record the backward run. The inhibitor solutions of concentration 5, 10 and 15 ppm were prepared in analytical grade chemical reagents using distilled water. For each experiment, a freshly prepared solution was used. The polyacrylamide is formed through the action of free radical initiators, the dissolved monomers are induced to polymerize to form the resultant polymer and the structure of acrylamide repeating unit has been listed in Figure 1.

Figure 1: Structure of polyacrylamide.

Results and Discussion

Monitoring of bacterial growth

Figure 2 shows the relation between bacterial counts with elapsed time in circulating water system. The data proved that the bacterial growth reached more than one million colonies per ml in just 24 hour, which indicate that conditions from temperature, nutrients and pH are suitable for ideal growth of general kinds of bacteria. The most kind of bacteria in this situation is aerobic bacteria and as we noticed in the cooling water system there is no sessile bacteria formed in the first 24 hours. The biofilm formed on the mild steel coupon is noticed after 72 hours, which indicates that the sessile bacteria take more time to be noticed. This experiment was carried out in absence of PAA to establish the required time for injection of the biocide and it is found that the proper time for monitoring the planketonic bacteria is started from 24 hours and 72 for sessile bacteria.

Figure 2: Monitoring of bacterial counts of general kinds of bacteria versus time in absence of PAA.

The effect gradual concentration of PAA on the microbial growth at 1 and 24 hours are investigated and the data are listed in Figure 3. The data show that the time is very important in the inhibition of microbial growth, which is meaning the PAA need more time to give its highest effect. These results proved that the PAA has low penetration effect, which is also clearly noticed in the gained data in Figure 4.

Figure 3: Effect of different concentrations of polyacrylamide on the bacterial counts of general kinds of bacteria after 1 and 24 hrs of injection.

Figure 4: Inhibition efficiency of different concentration of polyacrylamide on the planktonic and sessile bacterial.

The planketonic bacteria are quickly affected by the presence of PAA because the inhibition of bacterial growth in these kinds of bacteria is directly attacked by the biocide and there is no need for penetration effect. In case of sessile bacteria the biocide must have additional properties to get the highest effect as penetration properties and these properties is existed in surfactants. The PAA shows moderate effect in sessile bacteria and need an extensional time to get the required effect. The time is very important if we need to use this biocide in the field of application so it is recommended to use it in case of inhibition of growth of planketonic bacteria but if we need to use it in sessile bacteria it is recommended to add suitable surfactant with a suitable dose to get the highest performance of biocidal activity of PAA.

The biocidal activity has been evaluated in the three doses for PAA with time and the aim of this experiment is determining the performance time per each dose to identify the time of cyclic injection. The water is circulated till the bacterial counts reaches one hundred thousand colony per ml and then the PAA is injected with 5, 10 and 15 ppm and then samples with time are taken till the bacterial counts return again to the start number of colony per ml, see Figure 5. The results show that bacterial counts is rapidly affected in all doses but there are difference in the effective duration time, since the time of cyclic injection at bacterial counts of 1000 colony per ml are 40, 55 and 70 hours at 5, 10 and 15 ppm respectively. To protect the cooling water from the infection of general kinds of bacteria, it is preferable to use PAA at 15 ppm and it is recommended to make the cyclic injection after 70 hours from first addition. To achieve the same results in presence of sessile bacteria it is recommended to add suitable surfactant in addition of PAA to improve its quality in mitigation of microbial activity.

Figure 5: Effect of time on the bacterial counts of general kinds of bacteria at different concentrations of polyacrylamide.

Electrochemical measurements

Open circuit potential: Figure 6 shows the open circuit potential of mild steel electrode at different concentration of PAA. The results show that the values of the registered open circuit potentials are shifted towards more positive potential. The values of open circuit potential are -630.0, -621.0, -609.0 and -574.0 and as we see the values shifted gradually to more positive values, which represent the concentration of PAA starts from zero, 5, 10 and 25 ppm of PAA. Shifting the values of open circuit potential to more positive prove that the behavior go to control the corrosion of mild steel in chloride media.

Figure 6: Open circuit potential curves of mild steel in 3.5% NaCl solution in absence and presence of different concentrations of PAA.

Potentiodynamic polarization: The effect of PAA concentration on the corrosion behavior of mild steel in sodium chloride solution was also tested by using the potentiodynamic polarization method and results are presented in Figure 7. The results show that the corrosion rate is decreased with increasing the concentration of PAA and the inhibition efficiency is increased gradually from 62.4, 69.8 and 80.9 for the concentrations of 5, 10 and 25 respectively. On the other hand the current densities were estimated in absence and in the presence of PAA by using Gamry soft ware and the obtained data are 31.50, 11.90, 8.90 and 6.03 μA cm-2 in absence and in the presence of 5, 10 and 25 ppm respectively. For the corrosion behavior results at the previous concentrations it is acceptable in case of the main aim is using the PAA as biocide but if we want to use it as corrosion inhibitor we recommend that increasing the dose to improve the performance of inhibition efficiency.

Figure 7: Potentiodynamic polarization curves of mild steel in 3.5% NaCl solution in absence and presence of different concentrations of PAA.

The potentiodynamic polarization data is presented in Table 1 and the results show that the OCP shifted to more positive potential and the data are -630.0, -621.0, -609.0 and -574.0 for zero inhibitor concentration, 5, 10 and 25 ppm respectively. The current density decreases gradually with the increasing of inhibitor and in the same time the corrosion rate decrease with the increment of concentration. By the way the inhibition efficiency is increase with concentration PAA concentration.

Inhibitor concentration ppm OCP (mV)Vs. SCE Ecorr (mV)Vs. SCE ba(mV dec-1) bc(mV dec-1) Icorr (µA cm-2) C.R, mpy
       IE %
Blank -630.0 -888.0 284.4 169.1 31.50 18.38
5 -621.0 -842.0 172.7 154.4 11.90 6.91/62.4%
10 -609.0 -834.0 162.3 146.3 8.90 5.55/69.8%
15 -574.0 -823.0 160.8 139.7 6.030 3.51/80.9%

Table 1: Electrochemical parameters and inhibition efficiency for mild steel in 3.5% NaCl containing different concentrations of PAA.

Electrochemical impedance measurements: The Nyquist plots curves of electrochemical impedance spectroscopy curves, which show the relation between the impedance and the concentration of the inhibitor, are presented in Figure 8. The data shows that the trend is clearly seen i.e., the impedance increases with increase the PAA concentration. The impedance parameters obtained from the equivalent circuit are listed in Table 2. Rf represents the solution resistance between working electrodes and the reference electrode, Ru and Cc are the resistance and capacitance of oxide layer, RPo and Cf are the resistance and capacitance of protective film. The percentage inhibition efficiency (IE%) was calculated from the Rp resistance values. From the data cited in Table 2 the inhibition efficiencies are 22.2, 44.6 and 58.5 for 5, 10 and 25 respectively. It is well known that the impedance is inversely proportional with the corrosion rate and this behavior is seen from the Rp values of untreated and treated solution, since the Rp values are 249.5, 320.0, 450.0 and 600.0 for untreated and treated with 5, 10 and 25 ppm of PAA respectively. It is clearly noticed that the impedance values were increased with increasing of the inhibitor concentration. Although the calculated inhibition efficiency from the impedance curves are lower than which calculated from polarization curves the same trend is obtained as mentioned in Figures 9 and 10. These results proved that the PAA has moderate effect against corrosion, so it is recommended to use PAA as biocide for controlling the bacterial growth in planketonic and sessile bacteria and in the same time it is safe for the metal surface and we can predict that the PAA could be have a synergistic effect if it added with a good corrosion inhibitor.

Inhibitor concentration ppm Rf
(ohm cm2)
Cc
(uFcm-2)
Ru
(ohm cm2)
Cf
( uFcm-2)
Rpo
(ohm cm2)
I.E, (%)
Blank 4.561 0.01319 25.28 1.29 249.5 -------
5 5.00 0.01291 2.58 3.25 320.0 22.2
10 4.00 0.01333 2.30 4.20 450.0 44.6
15 4.00 0.01442 2.28 5.09 600.0 58.5

Table 2: Electrochemical Impedance parameters and inhibition efficiency for mild steel in 3.5% NaCl containing different concentrations of PAA.

Figure 8: Nquist plots for mild steel in 3.5% NaCl in the absence and presence of different concentrations of PAA.

Figure 9: The equivalent circuit.

Figure 10: Comparison between the calculated inhibition efficiencies from the obtained data from potentiodynamic polarization results and electrochemical impedance spectroscopy.

Conclusions

Polyacrylamide with concentration range of 5, 10 and 25 ppm is showed acceptable results in both planketonic and sessile bacteria in circulating water which is considered the main task of our paper. The polyacrylamide is also subjected to corrosion control of mild steel insalt water to magnify its benefits to be used as biocide and corrosion inhibitor in cooling water. The cyclic injection of polyacrylamide is also tested to suggest the proper time for the re addition process for continuous control of bacterial growth and it is found that if we use the dose of 25 ppm we can recommended that the cyclic injection could be done after 70 hours from the first addition of biocide. The electrochemical measurements prove that the trend or behavior of polyacrylamide is stable in all electrochemical techniques with narrow difference in inhibition efficiencies.

References

--
Post your comment

Share This Article

Article Usage

  • Total views: 12287
  • [From(publication date):
    June-2016 - Nov 21, 2024]
  • Breakdown by view type
  • HTML page views : 11455
  • PDF downloads : 832
Top